Applied Energy Solutions Ferroresonant Chargers
The Workhorse Series 1 electric forklift battery charger utilizes single phase AC power. It is designed for moderate use where a 16 hour recharge is possible. This is ideal for applications where 3-phase power is unavailable; for example, small business and light duty applications.The WorkHorse Series 1 chargers feature full automation and a 2 year parts and labor warranty through the manufacturer.
Rugged, single-shift capacity charger where consistency, reliability and efficiency are key factors without the pressure of recharge time.
Features & Benefits:
- Fully integrated microprocessor control for automatic volt/time termination
- Selectable refresh charge for 30 minutes every 24 hours
- Ten to sixteen hours charge time.
- Auto start with five second delay
- Selectable one hour time delay
- Memory retention during AC power loss
- Automatic shutdown for the following conditions:
- 80% charge does not occur in twelve hours
- Volts per cell are too high or too low
- Charging current is too low
- Battery cable is disconnected while charging
- Ferroresonant tapered charge for optimum battery and charger life
- Selectable 80% voltage of 2.37 or 2.45 volts per cell
- Digital display for showing:
- Charge current
- Fault codes
- Multi color LED’s indicating charging status, equalization mode and fault shutdown
- Red push button for manual shutdown
- Manual jump start for over-discharged batteries
- Manual equalize button
- Supplied with seven foot AC line cord and plug (line cord not provided on 12A750, 18A450, 18A600, 18A750, 24A600 @120V AC)
- Ten foot long output cables for added flexibility
- Numerous Output connectors available as standard
Product Safety:
- UL Listed
- UL Listed to Canadian safety standards
- AC Specifications three phase 480 VAC
Optional Features:
- Wall mount
Important Downloadable Information:
The most dependable dual-shift charger on the market. Fully recharges a normally depleted lead acid battery in eight hours or less.Features & Benefits:
- Fully integrated microprocessor control for automatic dv/dt di/dt termination
- Interface jack for remote control and monitoring options
- Automatic refresh charge every twelve hours
- Charge time of eight hours or less on a normally discharged battery
- Auto start with five second delay
- Selectable delayed start from one to nine hours
- Battery protection with override timers, wrong battery sensing and negative charge slope termination
- Automatic shutdown for the following conditions:
- 80% charge does not occur in nine hours
- Final charge is not reached six hours after 80% (gassing point)
- Volts per cell are too high or too low
- Charging current is too low
- Battery cable is disconnected while charging
- Ferroresonant tapered charge for optimum battery and charger life
- Selectable 80% voltage of 2.37 or 2.45 volts per cell
- Four position Digital display for showing:
- Charge current
- Equalize in process
- Fault diagnostics
- Four LED indicators showing charge status including:
- Charging
- 80% Charged
- Charge Complete
- Fault Shutdown
- Red push button for manual shutdown
- Manual jump start for over-discharged batteries
- Manual and or Automatic equalization
- Ten foot long output cables for added flexibility
- Numerous Output connectors available as standard
Product Safety:
- UL Listed
- UL Listed to Canadian safety standards
Optional Features:
- Wall Mount brackets available
- Remote Control Box available
- Fungus protection available
Important Downloadable Information:
The industry’s most technologically advanced and dependable heavy-duty charger for multi-shift applications requiring a full battery recharge in less than eight hours.Features & Benefits:
- Fully integrated microprocessor control for automatic dv/dt di/dt termination
- Interface jack for remote control and monitoring options
- Automatic refresh charge every twelve hours
- Charge time of eight hours or less on a fully discharged battery
- Auto start with five second delay
- Selectable delayed start from one to nine hours
- Battery protection with override timers, wrong battery sensing and negative charge slope termination
- Automatic shutdown for the following conditions:
- 80% charge does not occur in nine hours
- Final charge is not reached six hours after 80% (gassing point)
- Volts per cell are too high or too low
- Charging current is too low
- Battery cable is disconnected while charging
- Ferroresonant tapered charge for optimum battery and charger life
- Selectable 80% voltage of 2.37 or 2.45 volts per cell
- Four position Digital display for showing:
- Charge current
- Equalize in process
- Fault diagnostics
- LED test button
- Charger data monitor button
- Provides AH returned, Total charge time, Average volts per cell
- Cool down timer initiates at the end of charge
- Red push button for manual shutdown
- Manual jump start for over-discharged batteries
- Manual and or Automatic equalization
- Ten foot long output cables for added flexibility
- Numerous Output connectors available as standard
Product Safety:
- UL Listed
- UL Listed to Canadian safety standards
Optional Features:
- Wall Mount brackets available
- Remote Control Box available
- Fungus protection available
- Real Time Clock Control
- 50HZ models available
- Water signal (driver circuit and valve available as options)
- Series and Parallel output cables available
Important Downloadable Information:
Contact Us Now
Industrial Battery of Pittsburgh distributes Applied Energy Solutions ferroresonant chargers!
Contact us today for more information or to place an order!
Contact Us Now